TMS Signal Generator Signals
============================
AWG PUPE Description
===================================
1 Ana1-a Sigma
2 Ana1-b DeltaX = 0.2 * Sigma;
3 Ana1-b DeltaY = -0.1 * Sigma;
4 RefClk SYSTEM_CLOCK
5 T7 FREF = 470KHz square (should this be pulsed ?)
6 T5 Injection (or SYSTEM_CLOCK = 10MHz square ??)
7 T6 H_CHANGE = +ve pulse 100ns
8 T1 CYCLE_START = +ve pulse 100ns
Marker T2 CYCLE_END = +ve pulse 100ns
Timing Panel to PUPE
=====================
T1 J26
T2 J19 CYCLE_START
T3 J13 CYCLE_END
T4 J20 CAL_START
T5 J17 CAL_END
T6 J22 INJECTION
T7 J16 H_CHANGE
T8 J27 FREF